7.3.6. Check of return of an anchor of the traction relay

Disconnect a stator winding wire from a conclusion of "M" of the traction relay.

Fig. 7.60. Scheme of check of return of an anchor of the traction relay


Connect wires from plugs of 12 V of the rechargeable battery to a conclusion of "M" and the case of a starter (fig. 7.60).

ATTENTION
It is necessary to make this check quickly, no more than 10 with, for prevention of burn-out of a winding of a starter.

Put forward a hand the leading gear wheel and release. If the leading gear wheel at once comes back to a starting position, the traction relay regularly means. If is not present, then replace the traction relay.